PME110-TR0ING 120V 10A Electronic Protector for Refrigerators

BREAKERMATIC DOMESTIC FRIDGE
SKU: PME110-TR0ING
Categoría:
Voltaje de Alimentación 120 VAC
Máxima carga 10 A
Tensiones de salida permitidas 95V - 138V +/- 3%
Retardo de encendido 3:50 min +/- 20%
Frecuencia 50/60 Hz
Descargar catálogo(s)
Catalog 2023, Pg 6 Refrigerator protector
Technical Datasheet PME
Etiquetas:
SKU: PME110-TR0ING
Categoría:
Voltaje de Alimentación 120 VAC
Máxima carga 10 A
Tensiones de salida permitidas 95V - 138V +/- 3%
Retardo de encendido 3:50 min +/- 20%
Frecuencia 50/60 Hz
Descargar catálogo(s)
Catalog 2023, Pg 6 Refrigerator protector
Technical Datasheet PME
Etiquetas:

The BREAKERMATIC REFRIGERATORS 110V has been specially designed to prevent damage that a blackout or high/low voltage can cause to your refrigerator or refrigeration equipment. The BREAKERMATIC REFRIGERATORS 110V  will disconnect your equipment when a power failure occurs and will keep it disconnected as long as the failure lasts and for the time necessary to equalize the pressures of the refrigeration system. It then reconnects your device automatically.

This model is provided with type B (NEMA 5-15) plug and receptacle.

Easy to install and guaranteed protection 24 hours a day! Connect the plug or plug of your equipment to the BREAKERMATIC REFRIGERATORS 110V , and it directly to the wall outlet.

Ideal for:

  • Domestic Freezers
  • Water coolers
  • Domestic Refrigerators up to 27 cubic feet
  • Executive Refrigerators

Operation 

  1. Protection against voltage variations in steady state. The BREAKERMATIC Refrigerators disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain out of range longer than the response time for the disconnection to be activated. As long as the fault remains, the corresponding high or low voltage indicator will remain on.
  2. Reconnection delay or waiting cycle. Upon energizing the protector, or upon completion of a voltage fault, the protector will initiate a time delay before connecting the output. The duration of the time delay is indicated in the specifications. The on-delay is designed to allow equalization of cooling system pressures following a service interruption.
  3. Detection of blackouts, “sag”, etc. The protector will disconnect the load if it detects a sudden voltage drop below 50% of the nominal voltage and will initiate a delay cycle.

Additional information

Weight 145 kg