PME110-TR0ING REFRIGERATOR – Electronic Voltage Protector for Conventional Refrigerator (english edition)

BREAKERMATIC Refrigerator

120VAC 10A with grounding pole, for convetional refrigerators.

SKU: PME110-TR0ING
Category:
Nominal Voltage 120 VAC
Nominal current 10 A
Allowed output voltages 95 - 138 VAC +/- 3%
Turn on delay 3:50 min +/- 20%
Frequency 50/60 Hz
Download Catalog(s)
Catalog 2023 pg 6 Refrigerator protectors (eng.)
PME Datasheet (eng)
Labels: , , , , , , ,
SKU: PME110-TR0ING
Category:
Nominal Voltage 120 VAC
Nominal current 10 A
Allowed output voltages 95 - 138 VAC +/- 3%
Turn on delay 3:50 min +/- 20%
Frequency 50/60 Hz
Download Catalog(s)
Catalog 2023 pg 6 Refrigerator protectors (eng.)
PME Datasheet (eng)
Labels: , , , , , , ,

The BREAKERMATIC REFRIGERATORS  has been specially designed to prevent damage that a blackout or high/low voltage can cause to your refrigerator or refrigeration equipment. The BREAKERMATIC REFRIGERATORS  will disconnect your equipment when a power failure occurs and will keep it disconnected as long as the failure lasts and for the time necessary to equalize the pressures of the refrigeration system. It then reconnects your device automatically.

It comes with a  TYPE B  American plug, NEMA 5-15P with grounding pole,  and a type B outlet, NEMA 5-15R.

Easy to install and guaranteed protection 24 hours a day! Connect the plug or plug of your equipment to the BREAKERMATIC REFRIGERATORS , and it directly to the wall outlet.

Ideal for:

  • Domestic Freezers
  • Water coolers
  • Domestic Refrigerators up to 27 cubic feet
  • Executive Refrigerators

Operation 

Protection against voltage variations in steady state.

The BREAKERMATIC Refrigerators disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain out of range longer than the response time for the disconnection to be activated. As long as the fault remains, the corresponding high or low voltage indicator will remain on.

Reconnection delay or waiting cycle.

Upon energizing the protector, or upon completion of a voltage fault, the protector will initiate a time delay before connecting the output. The duration of the time delay is indicated in the specifications. The on-delay is designed to allow equalization of cooling system pressures following a service interruption.

Blackout and Brownout Detection.

The protector will disconnect the load if it detects a sudden voltage drop below 50% of the nominal voltage and will initiate a delay cycle.

Additional information

Weight 145 kg