PLA110-150EST Electronic Voltage Protector for Dishwasher, Washing and Drying Equipment in 110V
Breakermatic Lavadoras
120V 15A (Spanish edition)
For washing machines, dishwashers, dryers (120V)
The BREAKERMATIC WASHING MACHINE has been specially designed to prevent damage to your washing machine, dryer, or dishwasher caused by a blackout or temporary voltage variation (high or low). It also prevents damage caused by transient voltage spikes. The BREAKERMATIC WASHING MACHINE protector will disconnect the outlet in the event of a temporary voltage failure, a blackout, or a flickering, and will keep it disconnected for up to 5 seconds after the fault disappears. Additionally, the BREAKERMATIC WASHING MACHINE absorbs transient spikes produced by the operation of nearby loads or by atmospheric activity, preventing them from reaching your equipment without having to unplug it.
It has two type B or NEMA 5-15R outlets, allowing two devices to be connected simultaneously as long as the sum of the currents or wattages does not exceed 15A. For example, it is possible to connect a washer and gas dryer to the same unit.
The Type B plug (Nema 5-15P) allows direct connection to a wall outlet, without occupying the two positions of a duplex outlet.
Easy to install and guaranteed 24/7 protection!
Ideal for
- Washers
- Dryers (120V)
- Dishwashers
Models
PLA110-150EST 120V 15A (Spanish version)
Operation
Protection against steady-state voltage variations.
The BREAKERMATIC LAVADORAS disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain outside the range longer than the response time for the disconnection to be activated. While the fault persists, the corresponding high or low voltage indicator will remain illuminated.
Reconnection delay or wait cycle.
Upon energizing the protector, or upon termination of a voltage fault, the protector will initiate a time delay before connecting the output. The duration of the time delay is indicated in the specifications. The short connection delay is designed to allow the power grid to stabilize after a service interruption.
Blackout detection, sag detection, etc.
The protector will disconnect the load if it detects a sudden voltage drop below 50% of the nominal voltage and initiate a wait cycle.
Transient Overvoltage Suppression.
Transient over voltages are very short-duration, high-energy voltage spikes produced by the connection or disconnection of loads or induced by lightning strikes near the electrical grid, which propagate through it until they reach the equipment. The BREAKERMATIC LAVADORAS interrupts transient over voltages between phase and neutral (differential mode) and between each current-carrying line and ground (common mode) without disconnecting the output..