PIN110-E++ING AIR INVERTER – Plug-In Electronic Protector for Air Conditioners and Cooling Equipment of last generation INVERTER 110Vac 15A NEMA 5-15 (English Edition)

BREAKERMATIC Aire 110 Inverter

120VAC 15A  Type B NEMA 5-15 (Spanish Edition)

For inverter type, mini split A/C and Refrigeration Equipment.

SKU: PIN110-E++ING
Category:
Nominal Voltage 120 VAC
Connections NEMA 5-15 P/R (Tipo B)
Nominal current 15 A
Transient Surge Suppression capability 0.6 kV / 6.5 kA / 3 x 158 J
Allowed output voltages 87VAC - 143 VAC +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Catalog Broshure Pg 16-17 Air 110 (Eng.)
Air 110 Inverter Technical datasheet (eng.)
Labels:
SKU: PIN110-E++ING
Category:
Nominal Voltage 120 VAC
Connections NEMA 5-15 P/R (Tipo B)
Nominal current 15 A
Transient Surge Suppression capability 0.6 kV / 6.5 kA / 3 x 158 J
Allowed output voltages 87VAC - 143 VAC +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Catalog Broshure Pg 16-17 Air 110 (Eng.)
Air 110 Inverter Technical datasheet (eng.)
Labels:

The BREAKERMATIC Air 110 INVERTER has been specially designed to prevent damage to your INVERTER-powered air conditioner caused by a blackout or a temporary voltage variation, whether too high or too low. It also prevents damage caused by transient voltage spikes.

The BREAKERMATIC Air 110 INVERTER protector will disconnect the output in the event of a temporary voltage failure, blackout, or flickering, and will keep it disconnected after the fault disappears, long enough to equalize the A/C system pressures. Additionally, the BREAKERMATIC Air 110 INVERTER absorbs transient spikes produced by the operation of nearby loads or atmospheric activity, preventing them from reaching your equipment without having to unplug it.

It features a Type B or NEMA 5-15R outlet, allowing you to connect air conditioning units equipped with a power cord and plug without cutting the cord.

The Type B (Nema 5-15P) plug allows direct connection to a wall outlet. The protector can be rotated over the outlet for convenient placement.

Easy to install and guaranteed 24-hour protection!

Ideal for

  • Mini-split air conditioners equipped with inverter technology or electronic controllers.
  • Refrigeration units with inverter compressors or electronic controllers.

Operation

Protection against steady-state voltage variations.

The BREAKERMATIC AIR 110 Inverter disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. In the case of adjustable equipment, the cut-off voltages can be set within the ranges indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain outside the range longer than the response time for the disconnection to be activated. While the fault persists, the corresponding high or low voltage indicator will remain illuminated.

Reconnection delay or standby cycle.

When the protector is energized, or at the end of a voltage failure, the protector will initiate a reconnection delay before connecting the output. The duration of the reconnection delay is indicated in the specifications. This standby cycle protects sensitive equipment from short cycles of operation, allowing, in the case of A/C and refrigeration equipment, system pressures to equalize before reconnecting.

Autostart.

This feature reduces the standby cycle to 5 seconds when the protector has been off for a considerable amount of time.

Blackout detection, sag detection, etc.

The protector will instantly disconnect the load if it detects a sudden voltage drop below 50% of the nominal voltage and will initiate a standby cycle.

Suppression of transient overvoltages.

Transient overvoltages are very short-duration, high-energy voltage spikes produced by the connection or disconnection of loads or induced by atmospheric discharges near the electrical grid. They propagate through it until they reach the equipment. The BREAKERMATIC AIR 110 INVERTER cuts transient overvoltages between phase and neutral (differential mode) and between each current-carrying line and ground (common mode) without disconnecting the output..

Additional information

Weight 380 kg
Dimensions 139 × 87 × 40 cm