PIN220-C++EST Aire INVERTER 220 C – Plug-In Electronic Protector for Inverter type Air Conditioners and Cooling Equipment of lastest generation 220Vac 15A NEMA 6-15 P/R (Spanish Edition)

BREAKERMATIC AIRE INVERTER 220 C

220VAC 15A, NEMA 6-15 Plug & Receptacle (Spanish Edition)

For inverter type or electronically controlled, mini-split  Air Conditioners and Refrigeration Equipment.

SKU: PIN220-C++EST
Category:
Nominal Voltage 220 VAC
Connections NEMA 6-15 P/R
Nominal current 15 A
Transient Surge Suppression capability 1 kV, 6.5 kA, 3x 280J
Cut-off voltage Low 176 V +/- 3% - High 267 V +/- 3%
Frequency 50 / 60Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Air 220 catalog brochure p 18-19 (Eng.)
Air Inverter 220 Technical Datasheet
Labels: , , , ,
SKU: PIN220-C++EST
Category:
Nominal Voltage 220 VAC
Connections NEMA 6-15 P/R
Nominal current 15 A
Transient Surge Suppression capability 1 kV, 6.5 kA, 3x 280J
Cut-off voltage Low 176 V +/- 3% - High 267 V +/- 3%
Frequency 50 / 60Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Air 220 catalog brochure p 18-19 (Eng.)
Air Inverter 220 Technical Datasheet
Labels: , , , ,

The BREAKERMATIC Aire  INVERTER 220 C is an electronic voltage protector specially designed to prevent damage to your air conditioning equipment caused by a blackout or temporary high or low voltage, as well as damage caused by transient surges. It is ideal for equipment equipped with a plug or socket, making it easy to install the protection without having to intervene in the equipment.

The BREAKERMATIC Aire INVERTER 220 C will disconnect your equipment in the event of a power failure and will keep it off for the duration of the failure and for the time necessary to equalize the pressures in the cooling system. It will then automatically reconnect your equipment. In addition, the BREAKERMATIC Aire 220 INVERTER C absorbs transient surges produced by the operation of nearby loads or atmospheric activity, preventing them from reaching your equipment without having to disconnect it.

Easy to install and guaranteed 24-hour protection! Connect the plug or jack of your equipment to the BREAKERMATIC Aire INVERTER 220 C, and this directly to the wall outlet.

In addition to air conditioning equipment, this protector can be used on any commercial refrigeration equipment equipped with a compatible plug. Its robust construction and high capacity make it ideal for heavy-duty applications.

Ideal for

  • Single-phase mini-split inverter air conditioners up to 15A
  • Latest-technology single-phase or inverter refrigeration equipment
  • Freezers with electronic controls and inverter compressors
  • Display cases, coolers, among others.
  •  

Connections and capacity:

The BREAKERMATIC Aire INVERTER 220 C can handle any device equipped with a compatible plug (NEMA 6-15). The use of external adapters is not recommended. You must also connect it to a wall outlet compatible with the protector's NEMA 6-15 plug to ensure sufficient current capacity.

Operation 

Protection against steady-state voltage variations.

The BREAKERMATIC AIRE INVERTER 220  C disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. In the case of adjustable equipment, the cut-off voltages can be set within the ranges indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain outside the range longer than the response time for the disconnection to be activated. While the fault persists, the corresponding high or low voltage indicator will remain lit.

Reconnection delay or standby cycle.

When the protector is energized, or at the end of a voltage failure, the protector will initiate a time delay before connecting the output. The duration of the time delay is indicated in the specifications. The wait cycle protects sensitive equipment from short operating cycles, allowing, in the case of A/C and refrigeration equipment, system pressures to equalize before reconnecting.

Autostart®.

This feature reduces the standby cycle to 5 seconds when the protector has been off for a considerable amount of time.

Detection of blackouts and sags

The protector will disconnect the load almost instantaneously, if it detects a sudden voltage drop below 50% of the nominal voltage,  initiating a standby cycle.

Suppression of transient over voltages

Transient over voltages are very short-duration, high-energy voltage spikes produced by the connection or disconnection of loads or induced by atmospheric discharges near the electrical grid. They propagate through it until they reach the equipment. The BREAKERMATIC AIRE INVERTER 220 C trims transient over voltages between phase and neutral (differential mode) and between each current-carrying line and ground (common mode) without disconnecting the output.