PIN110-D00EST AIRE 110 D – Plug-In Electronic Protector for Air Conditioners and Refrigeration Equipment NEMA 5-20 120V / 20A (Spanish edition)

BREAKERMATIC Aire 110 D

120V / 20A  NEMA 5-20 (Spanish Edition)

for High Capacity Air Conditioners and Refrigeration equipment.

SKU: PIN110-D00EST
Category:
Nominal Voltage 120 VAC
Connections NEMA 5-20 P/R
Nominal current 20 A
Cut-off voltage Low 93 VAC +/- 3% - High 138 VAC +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Catalog Broschure Pg 16 (eng.)
Plug In 110 technical datasheet (eng.)
Labels: , , , , , ,
SKU: PIN110-D00EST
Category:
Nominal Voltage 120 VAC
Connections NEMA 5-20 P/R
Nominal current 20 A
Cut-off voltage Low 93 VAC +/- 3% - High 138 VAC +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Catalog Broschure Pg 16 (eng.)
Plug In 110 technical datasheet (eng.)
Labels: , , , , , ,

The BREAKERMATIC Aire 110 D has been specially designed to prevent damage to your conventional air conditioning equipment caused by a blackout or high/low voltage.

This high-capacity model can handle up to 20A continuous and high inrush currents.

This model plugs into a 20A, standard NEMA 5-20 outlet. The outlet is also NEMA 5-20 and accepts NEMA 5-20 and Type B (NEMA 5-15) plugs.

The BREAKERMATIC Aire 110 D will shut down your equipment in the event of a power failure and will keep it shut down for the duration of the failure and for the time necessary to equalize the cooling system pressures. It will then automatically reconnect your equipment.

Easy to install and guaranteed 24-hour protection! Connect your equipment's plug or jack to the BREAKERMATIC Aire 110 D, and then directly to the wall outlet.

In addition to air conditioning equipment, this protector can be used on any commercial refrigeration equipment equipped with a cord and plug NEMA 5-20. Its robust construction and high capacity make it ideal for heavy-duty applications.

Ideal For: 

  • 110VAC – 127VAC air conditioners
  • Commercial display cases, refrigerated displays
  • Bottle racks, soft drink coolers, slush machines
  • Freezers
  • High-capacity equipment

Operation

Protection against steady-state voltage variations

The BREAKERMATIC AIRE 110 D disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage indicated in the specifications. For adjustable equipment, the cut-off voltages can be set within the ranges indicated in the specifications. The response time to a fault is typically 1 s. The voltage must remain outside the range longer than the response time for the disconnection to be activated. While the fault persists, the corresponding high or low voltage indicator will remain illuminated.

Reconnection delay or wait cycle

When the protector is energized, or at the end of a voltage fault, the protector will initiate a time delay before connecting the output. The duration of the time delay is indicated in the specifications. The wait cycle protects sensitive equipment from short operating cycles, allowing, in the case of A/C and refrigeration equipment, system pressures to equalize before reconnecting.

Autostart ®

This feature reduces the standby cycle to 5 seconds when the protector has been off for a considerable amount of time.

Blackout &  sag  detection

The protector will disconnect the load if it detects a sudden voltage drop below 50% of the rated voltage and will initiate a standby cycle.