PBE220-A00EST ULTRA 220 A – Electronic Voltage Protector 220 V 40 A, connected by terminal block, commercial enclosure, for Conventional Air Conditioners, Refrigeration Equipment, and electrical motors,

BREAKERMATIC ULTRA 220 A

Single phase 220 VAC  40A

for conventional refrigeration equipment, air conditioners, water pumps, pool pumps, electrical motors.

SKU: PBE220-A00EST
Category:
Nominal Voltage 220 VAC
Connections 6 pole Terminal Block
Nominal current 40 A
Cut-off voltage Low 176 V +/- 3% - High 253 V +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Ultra 220 Catalog Brochure Pg 22-23 (Eng.)
Ultra 220 Technical Datasheet (Eng.)
Labels:
SKU: PBE220-A00EST
Category:
Nominal Voltage 220 VAC
Connections 6 pole Terminal Block
Nominal current 40 A
Cut-off voltage Low 176 V +/- 3% - High 253 V +/- 3%
Frequency 50/60 Hz
Standby cycle 4 min ± 20%
Download Catalog(s)
Ultra 220 Catalog Brochure Pg 22-23 (Eng.)
Ultra 220 Technical Datasheet (Eng.)
Labels:

The BREAKERMATIC Ultra 220 A is a high-capacity electronic voltage protector specifically designed to prevent damage to refrigeration equipment caused by voltage fluctuations and other power supply disturbances.

It automatically protects your equipment, shutting it down when it detects excessively high or low voltage, or when a blackout or brownout occurs that could damage your refrigeration equipment. Upon detecting a voltage fault, the protector disconnects your equipment, and when the fault disappears, it initiates a standby cycle to allow the power grid to stabilize. In the case of refrigeration and air conditioning equipment, the standby cycle allows system pressures to equalize. Once the standby cycle is complete, the BREAKERMATIC Ultra 220 A  automatically reconnects your equipment.

The BREAKERMATIC Ultra 220 A is connected via a terminal block, which comes with a cover to protect against accidental electric shock. It includes a bracket for easy installation on a wall or inside the equipment to be protected.

You'll be able to see if there's a voltage failure, the standby cycle, and the protector's output on its four indicator lights.

Ideal for

  • Conventional Air Conditioners 
  • Conventional Refrigeration Equipment
  • Hydropneumatic Systems
  • Water Pumps
  • Pool Pumps
  • Electric Motors
  • Automatic Doors, Gates, and Garage Doors.

 

Operation

Protection against steady-state voltage variations.

The BREAKERMATIC Ultra 220 A disconnects the output if the steady-state voltage is above the high cut-off voltage or below the low cut-off voltage. The response time for voltage variations is typically 1 s. The voltage must remain outside the range longer than the response time for the disconnection to be activated. While the fault persists, the corresponding high or low voltage indicator will remain illuminated.

Reconnection delay or wait cycle.

Upon energizing the protector, or upon termination of a voltage fault, the protector will initiate a time delay before connecting the output. The time delay duration is typically 4 minutes. The wait cycle protects sensitive equipment from short operating cycles. For example, in the case of refrigeration or air conditioning equipment, it delays startup long enough to allow pressure equalization in the system.

Blackout and Brownout detection.

The protector will disconnect the load if it detects a sudden voltage drop below 50% of the nominal voltage and will initiate a standby cycle. The response time of the blackout detector is instantaneous; the minimum blackout duration is specified in the specifications, but it is guaranteed to be greater than the maximum transfer time on distribution lines.

Autostart®

The autostart feature reduces the reconnection delay or wait cycle to a few seconds if the protector has been de-energized for more than 10 minutes. This way, the protector will quickly turn on the output after a prolonged period of blackout or power loss.

Additional information

Weight 305 kg
Dimensions 139 × 87 × 40 cm